| Availability: | |
|---|---|
din3055
Visible Structural Features
Each visible strand is composed of multiple smaller metallic wires. This construction allows the rope to bend more readily than a solid steel rod of similar overall diameter.
The external strands follow a helical path along the rope. The exact lay direction, lay length and classification cannot be confirmed from the photographs.
The cut-end images show several strand bundles arranged around a central region. The precise construction code must be established by a supplier drawing or technical data sheet rather than visual estimation.
A fibrous-looking central material is visible in one opened cross-section. The images do not establish whether it is a natural-fibre core, synthetic-fibre core, mixed packing material or another construction. The core type must therefore be confirmed.
The rope has a bright silver-grey appearance. This does not prove whether the wire is galvanized, stainless steel, bright uncoated steel or treated by another process.
Item | Confirmed or observable information |
|---|---|
Product name | Steel Wire Rope, supplied by the user |
Form | Multi-wire, multi-strand rope |
Outer structure | Helically laid metallic strands |
Core area | Fibrous-looking material visible; exact type unconfirmed |
Surface appearance | Silver-grey metallic |
Supply form | Wound on a wooden reel in one image |
Sample measurement | Digital display reads approximately 8.08 mm |
Nominal diameter | 2~20mm |
Strand construction | 6×7+FC |
Lay direction and lay length | 1000m |
Steel grade | high-carbon steel |
Surface treatment | galvanized |
Tensile grade | 1570N/mm²、1770N/mm² |
Breaking force or working load | Based on diameter |
Standard | din3055 |
A complete technical description should identify:
number of strands;
number and arrangement of wires per strand;
core type and core material;
ordinary, parallel or other lay relationship;
right-hand or left-hand lay;
regular lay or lang lay, if applicable;
nominal rope diameter and tolerance;
individual wire diameter, where required;
compacted or non-compacted construction;
rotation characteristics;
lubrication condition;
steel grade and tensile designation;
surface treatment;
minimum breaking force;
applicable product and test standard.
None of these classifications should be inferred solely from the photographs.
Steel wire rope is generally selected as a flexible tensile component, but the supplied images do not identify the intended system. No specific lifting, hoisting, winching, suspension, tensioning or safety application is confirmed.
Before selection, the buyer should state:
intended equipment or assembly;
static or dynamic loading;
bending frequency;
sheave or drum conditions;
environmental exposure;
required flexibility;
termination method;
design factor;
inspection rules;
replacement criteria;
legal or industry requirements.
The rope should not be assigned to a load-bearing or safety-critical function until its full specification and certified performance are verified.
The user-provided product name confirms steel wire rope. The images do not identify the steel grade or chemical composition.
The silver-grey surface may correspond to several possible material or finish conditions. Therefore, an RFQ should explicitly define whether the project requires:
a particular carbon-steel grade;
stainless steel;
galvanized wire;
bright or uncoated wire;
another metallic coating;
lubrication;
corrosion testing;
material certificates;
coating-mass or coating-thickness verification.
No stainless-steel or galvanized claim is made in this description.
No end fitting or finished termination is shown. Installation must be engineered around the confirmed rope construction and the selected system.
Before installation:
verify the rope identification and specification;
confirm the measured diameter using the specified measurement method;
check reel condition and rope packaging;
inspect for crushing, kinks, corrosion or broken wires;
identify the pay-off direction;
select compatible drums, sheaves and end terminations;
follow the equipment designer’s installation procedure;
avoid uncontrolled twisting, reverse bending and sharp kinks;
inspect the completed termination;
document the installed rope and inspection baseline.
Exact termination hardware, torque, splice length and installation method are not provided by the images.
verify nominal diameter and tolerance;
confirm strand and wire construction;
identify lay direction and lay length;
inspect the cut end for construction consistency;
check the surface for visible damage;
inspect reel winding and flange condition;
verify material and coating documents;
confirm rope mass per unit length, if required;
review breaking-force certification;
check total supplied length;
maintain heat, lot or reel traceability where specified.
The caliper image displays approximately 8.08 mm for the pictured sample. The nominal diameter and permitted tolerance are not confirmed.
The metallic colour is not sufficient to identify galvanizing. Surface treatment must be confirmed separately.
The images do not establish stainless-steel composition. Only the general product name “steel wire rope” is provided.
The rope is visibly multi-strand, but the exact construction code cannot be reliably counted or classified from the images.
A fibrous-looking central material is visible, but its exact type and specification are unknown.
No lifting rating or certified breaking force is supplied. Lifting use must not be assumed without the correct specification, test documents and engineering approval.
Send the required nominal diameter, strand construction, core, lay, steel grade, surface treatment, rope length, minimum breaking force, application, standard, test documents, reel size and order quantity for confirmation.