| Availability: | |
|---|---|
din3055
DIN 3055 is the shorthand for the former German standard DIN 3055:1972, which applies to 6×7 round-strand steel wire ropes. It specifies technical requirements—such as rope diameter and minimum breaking force—rather than defining a specific product model based on a particular diameter or material. Although this standard has been superseded by DIN EN 12385-4, the term "DIN 3055" remains in common use as a designation for 6×7 steel wire ropes.
1. Product Structure and Cross-Section
A 6×7 steel wire rope, as defined by DIN 3055, consists of 6 strands, with each strand containing 7 individual wires, for a total of 42 wires.
2. Specifications and Performance
Nominal Tensile Strength: Common grades include 1570, 1770, and 1960 N/mm². This is a performance metric for the individual wires, not the allowable working load of the wire rope itself.
Minimum Breaking Force: Determined by referring to tables based on diameter, core type, and tensile strength grade. For a given diameter, ropes with an IWRC (Independent Wire Rope Core) typically offer a higher minimum breaking force than those with an FC (Fiber Core).
Diameter: Typically ranges from approximately 1 mm to 20 mm; some suppliers may offer larger diameters or custom lengths.
Surface Finish: Common options include galvanized, bright (oiled), or PVC-coated; stainless steel versions are also available.
Selection Considerations: The term "DIN 3055" only defines the construction and the governing standard; it does not specify the material, strength, or corrosion-resistance level. When purchasing, it is essential to explicitly specify the diameter, core type, nominal tensile strength, surface finish, and the applicable standard.
3. Applications and Usage Notes
The 6×7 construction is suitable for general-purpose applications, such as tensioning cables, suspension, fencing, marine rigging, and static lifting or securing tasks that do not involve frequent bending.
Choosing a Core: Opt for an IWRC when higher rigidity and breaking force are required; consider an FC (Fiber Core) when greater elasticity, cushioning, or internal lubrication is needed. Note on Bending: The 6×7 construction features thicker outer wires, making it unsuitable for repeated bending over small-diameter pulleys.
Load Calculation: The working load should not be based directly on the minimum breaking force; a safety factor must be applied in accordance with relevant standards.
Corrosion Protection and Inspection: For outdoor or salt-spray environments, hot-dip galvanized wire rope is preferred. During use, inspect for broken wires, wear, reduction in diameter, and deformation; replace the rope promptly if it meets the criteria for retirement.
Nominal diameter | Reference breaking load(kN) | Theoretical weight (kg/100m) |
|---|---|---|
2mm | 2.5 | 1.4 |
3mm | 5.6 | 3.1 |
4mm | 9.8 | 5.5 |
5mm | 15.3 | 8.6 |
6mm | 22.0 | 12.4 |
8mm | 39.1 | 22.0 |
10mm | 61.0 | 34.4 |